Switch: labelled reference, US style, sheet 1 of 2
Fig. 1
12Switch (SPST)
A switch symbol stands for a contact that either completes or breaks a path.
Fig. 2
12Push button, normally open
The momentary push buttons shown here change contact state while pressed and return to their drawn, unactuated state when released.
Fig. 3
12Push button, normally closed
Switch contacts are drawn in their normal status: the position they rest in with no force applied. A normally-open (NO) contact is drawn open and a normally-closed (NC) contact closed; for a momentary push button, normal means not pressed.
Fig. 4
COM12Switch (SPDT)
Poles count the separate circuits a switch controls; throws count the contact destinations available to each pole. An off position is not an additional throw.
Fig. 5
COM11A1BCOM22A2BSwitch (DPDT)
Poles count the separate circuits a switch controls; throws count the contact destinations available to each pole. An off position is not an additional throw.
Notes
- The terminal key and the sources are on sheet 2.
- Name
- Class
- Date
- Sheet
- 1 of 2
- Drawing
- Switch Labelled reference
- Style
- US style
- From
- circuitsymbols.com
- Licence
- CC BY 4.0
Switch: labelled reference, US style, sheet 2 of 2
| Fig. | Terminals | What the terminal is |
|---|---|---|
| 1–3 | 1, 2 | A single-pole, single-throw (SPST) switch has two terminals. Their left or right position on the page does not give them different electrical roles. |
| 4, 5 | COM, COM1, COM2 | In a double-throw switch the common terminal is the one the moving arm belongs to. |
| 4, 5 | 1, 2, 1A, 1B, 2A, 2B | Each throw terminal is one of the positions the arm can connect the common terminal to. |
Sources
- ModEL — Electrical Switches, §§3.1–3.3 (pp. 16–19), Tony R. Kuphaldt, retrieved 2026-09-22
Notes
- The Fig. numbers are those on sheet 1.
- Name
- Class
- Date
- Sheet
- 2 of 2
- Drawing
- Switch Labelled reference
- Style
- US style
- From
- circuitsymbols.com
- Licence
- CC BY 4.0